A/C BRACKET INSTALLATION
Figure 17. A/C Hoses, O-rings, Receiver Dryer and Retaining Hardware on Condenser Assembly.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  817    818    819    820    821  822  823    824    825    826    827  
img
.
TM 5-2410-240-23-3
0248
A/C HOSE INSTALLATION
000248
N OT E
Remove caps or plugs from A/C hoses and fittings and install A/C hoses as noted during
removal.
1. Install two new O-rings (Figure 16, Item 4) on two A/C hoses (Figure 16, Items 3 and 7) and apply refrigerant
compressor lubricating oil on O-rings.
2. Loosely connect two A/C hoses (Figure 16, Items 3 and 7) on condenser (Figure 16, Item 5).
3. Install convoluted tube (Figure 16, Item 10) and clamp (Figure 16, Item 9) on A/C hose (Figure 16, Item 3).
4. Install clamp (Figure 16, Item 9), washer (Figure 16, Item 11), and bolt (Figure 16, Item 1) on machine
(Figure 16, Item 2).
N OT E
Install tiedown straps as noted during removal.
5. Install two new tiedown straps (Figure 16, Item 8) on A/C hoses (Figure 16, Items 3 and 7).
6. Tighten two fittings (Figure 16, Item 6).
Figure 16. A/C Hoses, O-rings, and Retaining Hardware on Condenser Assembly.
0248
0248-20