TM 5-2410-240-23-3
0267
REMOVAL
000267
N OT E
Tag and mark hoses and fittings to aid installation.
Use a container to catch any fluid that maydrain from hoses or system. Dispose of fluid
IAW local policy and ordinances. Ensure all spills are cleaned up.
Cap or plug hoses and open ports.
1. Remove eight bolts (Figure 1, Item 5), washers (Figure 1, Item 4), four clamps (Figure 1, Item 3), and two
hoses (Figure 1, Items 8 and 7) from hydrostatic drive motors (Figure 1, Items 2 and 6).
2. Remove two O-rings (Figure 1, Item 1) from hoses (Figure 1, Items 8 and 7). Discard O-rings. Position hoses
aside.
Figure 1. Hoses on Hydrostatic Drive Motors.
0267