RIPPER TILT CYLINDER PRESSURE TEST CONTINUED
00032
3. Open door (Figure 13, Item 2) (TM 5-2410-241-10).
N OT E
Transmission filter shown removed for clarity.
4. Remove protective cap (Figure 13, Item 3) from fitting (Figure 13, Item 6).
5. Remove protective cap (Figure 13, Item 4) from fitting (Figure 13, Item 5).
6. Connect 177-7861 hose (Figure 13, Item 8) coming from implement pump discharge pressure port (Figure 13,
Item 9) to fitting (Figure 13, Item 6).
7. Connect 177-7862 hose (Figure 13, Item 7) coming from signal pressure port (Figure 13, Item 1) to fitting (Fig-
ure 13, Item 5).
Figure 13. Test Equipment Installation.
0032