TM 5-2410-241-23-1
0032
RIPPER TILT CYLINDER PRESSURE TEST CONTINUED
00032
8. Start machine and allow it to run for 15 minutes to reach normal operating temperature (TM 5-2410-241-10).
9. Raise ripper 2 feet (0.6 m) off the ground (TM 5-2410-241-10).
10. Set machine to HIGH IDLE (RABBIT MODE) on the throttle switch (TM 5-2410-241-10).
11. Slowly engage ripper tilt control to the FULL TILT position (TM 5-2410-241-10).
N OT E
Do not hold control lever in the LIFT position longer than 15 to 20 seconds.
12. Hold ripper tilt control in the FULL TILT position (TM 5-2410-241-10) and record pressure shown on the pres-
sure gauge (Figure 14, Item 1).
13. Pressure gauge (Figure 14, Item 1) should read 3,255 to 3,345 psi (22,450 to 23,050 kPa). If pressure is out of
specification, replace ripper tilt control valve (WP 0211).
14. Set machine to LOW IDLE (TURTLE MODE) on the throttle switch (TM 5-2410-241-10).
15. Lower ripper to the ground (TM 5-2410-241-10).
16. Turn ignition switch and battery disconnect switch to OFF position (TM 5-2410-241-10).
17. Release hydraulic system pressure (WP 0186).
18. Remove gauges.
19. Reinstall protective caps.
20. Close door (TM 5-2410-241-10).
Figure 14. Test Equipment Installation.
0032
END OF TASK