NATO SLAVE AND CABLES REPLACEMENT
Figure 2. NATO Slave Cables.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1156    1157    1158    1159    1160  1161  1162    1163    1164    1165    1166  
img
.
TM 5-2410-241-23-1
0053
WARN I N G
Make sure master battery switch is in OFF position before replacing NATO slave and
cables. Failure to follow this warning may result in injury or death to personnel or damage
to equipment.
NATO SLAVE REMOVAL
00053
1. Remove screw (Figure 1, Item 4), washer (Figure 1, Item 3) and tether (Figure 1, Item 5) from NATO slave cap
(Figure 1, Item 2). Place tether aside.
2. Remove NATO slave cap (Figure 1, Item 2) from NATO slave (Figure 1, Item 1).
Figure 1. NATO Slave Cap.