• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Radiator Filler Cap.
DRAIN AND FLUSHING PROCEDURE CONTINUED

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  522    523    524    525    526  527  528    529    530    531    532  
img
.
TM 5-2410-241-23-2
0113
DRAIN AND FLUSHING PROCEDURE CONTINUED
N OT E
Access panel (WP 0014) can be removed as an alternative to removing front bottom
guard for reaching coolant drain valves.
4. Remove front bottom guard (WP 0199).
5. Position coolant drain hose in suitable drain pan.
6. Open coolant drain valves (Figure 2, Item 1). Allow coolant to drain into a suitable drain pan.
7. Close coolant drain valves (Figure 2, Item 1).
8. Fill cooling system with clean water.
9. Start engine (TM 5-2410-241-10). Run engine for 90 minutes.
10. Stop engine (TM 5-2410-241-10). Open coolant drain valves and drain water into a suitable drain pan.
11. If contamination is present, flush system with water. Flush system until draining water is clear.
12. Close coolant drain valves (Figure 2, Item 1).
Figure 2. Coolant Drain Valves.
0113
0113-3