TM 5-2410-241-23-2
0164
REMOVAL
000164
N OT E
Note cable routing to aid installation.
Tag and mark all electrical connections to aid installation.
1. Position boot (Figure 1, Item 8) on starter cable (Figure 1, Item 3) aside.
2. Remove nut (Figure 1, Item 9), washer (Figure 1, Item 10), and starter cable (Figure 1, Item 3) from junction
block (Figure 1, Item 11).
3. Remove nut (Figure 1, Item 6), washer (Figure 1, Item 7), clamp (Figure 1, Item 1), clamp (Figure 1, Item 4),
fuse panel cable (Figure 1, Item 2), and starter cable (Figure 1, Item 3) from stud (Figure 1, Item 5).
4. Position starter cable (Figure 1, Item 3) aside.
Figure 1. Starter Cable.
0164