Figure 5. Weatherproof Connector - Female.
Figure 8. Weatherproof Connector - Male.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  995    996    997    998    999  1000  1001    1002    1003    1004    1005  
img
.
TM 5-2410-241-23-3
0296
WEATHERPROOF CONNECTOR REPAIR CONTINUED
N OT E
Perform steps 6 and 7 only if terminal was removed.
6. Using wire stripping tool, strip insulation from wire (Figure 6, Item 1) equal to depth of terminal (Figure 6,
Item 2).
7. Using crimping tool, securely crimp new terminal (Figure 6, Item 2) on wire (Figure 6, Item 1).
Figure 6. Female Terminal.
0296
8. Install sleeve (Figure 7, Item 6), and seal (Figure 7, Item 5) on harness (Figure 7, Item 7).
9. Install terminal (Figure 7, Item 4) on housing (Figure 7, Item 3).
10. Install seal (Figure 7, Item 2) and terminal lock (Figure 7, Item 1) on housing (Figure 7, Item 3).
Figure 7. Weatherproof Connector - Female.
0296
END OF TASK
0296-7