TM 5-2410-241-23-3
0296
WEATHERPROOF CONNECTOR REPAIR CONTINUED
8. Install sleeve (Figure 10, Item 4), and seal (Figure 10, Item 3) on harness (Figure 10, Item 5).
9. Install terminal (Figure 10, Item 2) on housing (Figure 10, Item 6).
10. Install terminal lock (Figure 10, Item 1) on housing (Figure 10, Item 6).
Figure 10. Weatherproof Connector - Male.
0296
END OF TASK
ELECTRICAL GROUND POINTS
000296
N OT E
Good electrical ground points are essential for the proper functioning of the electrical
system. Ground points on electrical components and machine frame must be maintained
in a clean and secure condition to minimize electrical problems.
1. Remove nut, locknut, lockwasher, screw, etc., connecting ground wire or ground cable to ground point on
electrical component or threaded stud on machine frame.
2. If necessary, clean dirt from ring terminal, surface of electrical component, ground point, and all mounting
hardware with detergent, water, and a scrub brush.
3. Remove any corrosion or rust with a wire brush and abrasive cloth.
4. Replace defective mounting hardware. Replace defective ring terminal IAW Ring Terminal Repair in this work
package.
5. Install ground wire or ground cable on ground point with mounting hardware and tighten securely.
END OF TASK