Figure 3. Ring Terminal Repair.
Figure 5. Weatherproof Connector - Female.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  993    994    995    996    997  998  999    1000    1001    1002    1003  
img
.
TM 5-2410-241-23-3
0296
MILITARY CONNECTOR REPAIR
000296
1. Slide shell (Figure 4, Item 1) back on wire (Figure 4, Item 2) to expose sleeve (Figure 4, Item 5).
2. Remove sleeve (Figure 4, Item 5) from terminal (Figure 4, Item 4) by pulling sleeve forward.
3. If defective, remove terminal (Figure 4, Item 4) from wire (Figure 4, Item 2) by cutting through wire (Figure 4,
Item 2) just behind terminal.
N OT E
Perform steps 4 through 6 only if terminal was removed.
4. Using wire stripping tool, strip insulation from wire (Figure 4, Item 2) to expose length of metal strands
(Figure 4, Item 3) equal to depth of terminal (Figure 4, Item 4).
5. Using crimping tool, securely crimp terminal (Figure 4, Item 4) to metal strands (Figure 4, Item 3) of wire
(Figure 4, Item 2).
6. Install sleeve (Figure 4, Item 5) on terminal (Figure 4, Item 4) by pushing sleeve over front of terminal until fully
seated.
7. Slide shell (Figure 4, Item 1) up wire (Figure 4, Item 2) and over sleeve (Figure 4, Item 5).
Figure 4. Military Connector Repair.
0296
END OF TASK
0296-5