Table 2. Engine Troubleshooting with Codes - Continued.
Table 2. Engine Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  382    383    384    385    386  387  388    389    390    391    392  
img
. . . . . . . .
TM 5-2410-240-23-1
0019
Table 2. Engine Troubleshooting with Codes - Continued.
0019
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
N OT E
0110-04 Engine Coolant Temperature
Sensor Voltage Below Normal Code
Wait at least 30 seconds in order for diagnostic codes to become
Continued
active.
5. Using MSD (WP 0016), select
0110-03 Becomes Active - Sen-
engine ECM C6.6 D6K and
sor faulty. Replace engine coolant
check if diagnostic code 0110-
temperature sensor (WP 0056).
03 is active.
Verify proper operation of machine
(TM 5-2410-240-10).
0110-04 Remains Active -
Proceed to Test Step 2.
Test Step 2: Test Harness Sig-
nal Circuit.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect engine ECM har-
ness connector E-C1
(WP 0018, Figure 102) from
engine ECM J2.
3. Using digital multimeter
Continuity - Engine control wiring
(WP 0283), test for continuity
harness is shorted. Replace
between ECM harness con-
engine control wiring harness
nector E-C1 (WP 0018,
(WP 0052). Verify proper operation
Figure 102) terminal 43 and all
of machine (TM 5-2410-240-10).
other terminals in ECM har-
No Continuity - Proceed to step 4.
ness connector E-C1
(WP 0018, Figure 102).
4. Using digital multimeter
Continuity - Engine control wiring
(WP 0283), test for continuity
harness is shorted. Replace
between ECM harness con-
engine control wiring harness
nector E-C1 (WP 0018,
(WP 0052). Verify proper operation
Figure 102) terminal 43 and
of machine (TM 5-2410-240-10).
ground.
No Continuity - ECM faulty.
Replace engine ECM (WP 0049).
Connect E-C10 (WP 0018,
Figure 110) to engine coolant tem-
perature sensor.
Verify proper operation of machine
(TM 5-2410-240-10).
0168-00 Electrical System Voltage
1. Connect MSD (WP 0016).
High
Select engine ECM C6.6 D6K
and verify 0168-00 is active.
0019-68