Figure 5. O-rings and Fitting on Hydraulic Fan Gear Pump.
Figure 7. O-ring on Tube.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  695    696    697    698    699  700  701    702    703    704    705  
img
.
TM 5-2410-240-23-2
0123
INSTALLATION CONTINUED
N OT E
Remove caps or plugs from hose, line, and fitting.
Install hose, line, and fitting as noted during removal.
6. Install hydraulic fan gear pump (Figure 6, Item 3) and two bolts (Figure 6, Item 8) on implement pump
(Figure 6, Item 7).
7. Position fitting (Figure 6, Item 5) and tighten nut (Figure 6, Item 4).
8. Connect line (Figure 6, Item 1) and hose (Figure 6, Item 6) on fitting (Figure 6, Item 5) and tighten two tube
nuts (Figure 6, Item 2).
Figure 6. Line, Hose, Fitting, Hydraulic Fan Gear Pump, and Retaining Hardware.