Figure 7. O-ring on Tube.
IMPLEMENT PUMP REPLACEMENT (WITH WINCH)

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  697    698    699    700    701  702  703    704    705    706    707  
img
. . .
TM 5-2410-240-23-2
0123
INSTALLATION CONTINUED
N OT E
Remove caps or plugs from hose, tube, and open ports.
Install hose and tube as noted during removal.
11. Connect hose (Figure 8, Item 3) on tube (Figure 8, Item 7).
12. Connect hose (Figure 8, Item 3) on hydraulic tank (Figure 8, Item 4).
13. Install tube (Figure 8, Item 7), four washers (Figure 8, Item 1), and bolts (Figure 8, Item 8) on hydraulic fan
gear pump (Figure 8, Item 2).
14. Tighten two hose clamps (Figure 8, Items 5 and 6).
Figure 8. Hose, Tube, and Retaining Hardware.
0123
END OF TASK
FOLLOW-ON TASKS
000123
1. Install rear bottom guards (WP 0156).
2. Install rear cab floor plates (WP 0205).
3. Fill hydraulic fluid (WP 0160).
4. Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE