Figure 3. Hoses, Bracket, Manifold, Winch Piston Pump, and Retaining Hardware.
Figure 5. O-ring on Winch Piston Pump.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  702    703    704    705    706  707  708    709    710    711    712  
img
.
TM 5-2410-240-23-2
0124
REMOVAL CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support. Ensure lifting
device used is in good condition and of suitable load capacity. Keep clear of heavy parts
supported only by lifting device. Failure to follow this warning may cause injury or death to
personnel.
N OT E
Implement pump weighs approximately 60 lb (27 kg).
16. With assistance, remove two bolts (Figure 4, Item 2), washers (Figure 4, Item 3), and implement pump
(Figure 4, Item 1) from winch piston pump (Figure 4, Item 4).
17. Place implement pump (Figure 4, Item 1) on flat level surface.