• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Cable Retainer Below Junction Box.
Figure 4. Cable Retainer Below Junction Box.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  886    887    888    889    890  891  892    893    894    895    896  
img
.
TM 5-2410-240-23-2
0143
REMOVAL CONTINUED
N OT E
Tag and mark electrical connectors to aid installation.
4. Position boot (Figure 3, Item 2) aside.
5. Remove nut (Figure 3, Item 6), washer (Figure 3, Item 5), cable (Figure 3 Item 1), and washer (Figure 3,
Item 4) from junction block (Figure 3, Item 3).
Figure 3. Cable Connection at Junction Block.
0143
END OF TASK
CLEANING AND INSPECTION
000143
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0282).
END OF TASK
0143-4