Figure 4. Hoses and Fittings on Winch Piston Pump.
Figure 6. Hose and Fitting on Winch Piston Pump.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1119    1120    1121    1122    1123  1124  1125    1126    1127    1128    1129  
img
.
TM 5-2410-240-23-2
0159
WINCH PUMP CHARGE HOSES AND TUBES REMOVAL CONTINUED
N OT E
Tag and mark hoses and fittings to aid installation.
Note routing of hoses and tubes to aid installation.
Cap or plug hoses and fittings.
9. Loosen two tube nuts (Figure 5, Item 7) and disconnect hoses (Figure 5, Item 8) from tubes (Figure 5, Item 3).
Remove hoses from machine.
10. Loosen two tube nuts (Figure 5, Item 2) and disconnect tubes (Figure 5, Item 3) from fittings (Figure 5, Item 1).
11. Remove two nuts (Figure 5, Item 6) and tubes (Figure 5, Item 3) from bracket (Figure 5, Item 5). Remove tubes
from machine.
12. Remove four O-rings (Figure 5, Item 4) from two tubes (Figure 5, Item 3) and fittings (Figure 5, Item 1). Discard
O-rings.
13. Remove two bolts (Figure 5, Item 10), washers (Figure 5, Item 9), and bracket (Figure 5, Item 5) from machine.
Figure 5. Hose and Tube Connections.
0159
END OF TASK