TM 5-2410-240-23-3
0197
DISASSEMBLY CONTINUED
C AU T I O N
Mark each valve to identify its location to aid installation. Valves installed in the incorrect
order may cause damage to equipment.
5. Remove blade angle control valve (Figure 7, Item 5) from bolts (Figure 7, Item 4).
N OT E
Note location and size of O-rings to aid installation.
6. Remove two fittings (Figure 7, Item 1) and four O-rings (Figure 7, Item 2) from blade angle control valve
(Figure 7, Item 5). Discard O-rings.
N OT E
During removal, O-rings may stick to either side of valve face.
Note location and size of O-rings to aid installation.
7. Remove six O-rings (Figure 7, Item 3) from blade angle control valve (Figure 7, Item 5). Discard O-rings.
Figure 7. Blade Angle Control Valve.
0197