TM 5-2410-240-23-3
0197
DISASSEMBLY CONTINUED
C AU T I O N
Mark each valve to identify its location to aid installation. Valves installed in the incorrect
order may cause damage to equipment.
17. Remove blade lift control valve (Figure 13, Item 5) from bolts (Figure 13, Item 4).
N OT E
Note location and size of O-rings to aid installation.
18. Remove two fittings (Figure 13, Item 1) and four O-rings (Figure 13, Item 2) from blade lift control valve
(Figure 13, Item 5). Discard O-rings.
N OT E
During removal, O-rings may stick to either side of valve face.
Note location and size of O-rings to aid installation.
19. Remove six O-rings (Figure 13, Item 3) from blade lift control valve (Figure 13, Item 5). Discard O-rings.
Figure 13. Blade Lift Control Valve.
0197