Figure 8. Valve Solenoid Cover.
Figure 11. Valve Solenoid Cover.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  228    229    230    231    232  233  234    235    236    237    238  
img
.
TM 5-2410-240-23-3
0197
DISASSEMBLY CONTINUED
C AU T I O N
Mark each valve to identify its location to aid installation. Valves installed in the incorrect
order may cause damage to equipment.
11. Remove blade tilt control valve (Figure 10, Item 5) from bolts (Figure 10, Item 4).
N OT E
Note location and size of O-rings to aid installation.
12. Remove two fittings (Figure 10, Item 1) and four O-rings (Figure 10, Item 2) from blade tilt control valve
(Figure 10, Item 5). Discard O-rings.
N OT E
During removal, O-rings may stick to either side of valve face.
Note location and size of O-rings to aid installation.
13. Remove six O-rings (Figure 10, Item 3) from blade tilt control valve (Figure 10, Item 5). Discard O-rings.
Figure 10. Blade Tilt Control Valve.