TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
1. If continuity is found, proceed to
Facing Flood Lamp(s)
0296), test for continuity between
step 17.
Do Not Work - Continued
pin 3 on left rear flood lamp har-
left rear flood lamp harness (WP
103) and pin 1 on left rear flood
0154). Ensure all harness con-
lamp harness connector TK-C2
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
1.
If continuity is found, replace fuel
0296), test for continuity between
tank harness (WP 0170). Ensure
pin 4 on left rear flood lamp har-
all harness connectors are recon-
nected. Verify correct operation of
Figure 103) and pin 2 on left rear
machine (TM 5-2410-241-10).
flood lamp harness connector TK- 2.
left rear flood lamp harness (WP
0154). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
18. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
19. Disconnect right rear flood lamp
harness connector TJ-C2 (WP
0018, Figure 102) from right side
ROPS- mounted forward facing
flood lamp.
20. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
21. Turn main light switch to Flood-
light position (TM 5-2410-241-10).
1. If 24 Volts is found, proceed to
0296), measure for voltage
step 23.
between pin 1 and 2 on right rear
2. If 24 Volts is NOT found. Proceed
flood lamp harness connector TJ-
to step 29.
23. Turn main light switch to OFF
position (TM 5-2410-241-10).
24. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
25. Remove and disassemble right
ROPS-mounted forward facing
flood lamp (WP 0210).
0022-16