Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  730    731    732    733    734  735  736    737    738    739    740  
img
. .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
50. Using digital multimeter (WP
1.
If continuity is found, proceed to
Facing Flood Lamp(s)
0296), test for continuity between
step 51.
Do Not Work - Continued
pin 1 and terminal 4 on left ROPS- 2.
If continuity is NOT found, replace
mounted forward facing flood
left ROPS-mounted forward fac-
lamp (WP 0018, Figure 180).
ing flood lamp assembly (WP
0252). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
51. Using digital multimeter (WP
1. If continuity is found, replace left
0296), test for continuity between
ROPS-mounted forward facing
pin 2 and terminal 3 on left ROPS
flood lamp bulb (WP 0252).
-mounted forward facing flood
Ensure all harness connectors
lamp (WP 0018, Figure 180).
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
2. If continuity is NOT found, replace
left ROPS-mounted forward fac-
ing flood lamp assembly (WP
0252). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
52. Turn main light switch to OFF
position (TM 5-2410-241-10).
53. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).