TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
67. Disconnect platform harness con-
Facing Flood Lamp(s)
Do Not Work - Continued
21) from fuse panel harness con-
Figure 22).
68. Turn main light switch to Flood-
light position (TM 5-2410-241-10).
1. If continuity is found, replace fuse
0296), test for continuity between
panel harness (WP 0176). Ensure
pin 30 on platform harness con-
all harness connectors are recon-
nected. Verify correct operation of
Figure 21) and machine ground.
machine (TM 5-2410-241-10).
ceed to step 70.
70. Disconnect instrument panel har-
Figure 100) from main light switch
(WP 0262).
0296), test for continuity between
step 72.
pin 1 and pin 8 on main light
switch.
main light switch (WP 0262).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
72. Disconnect fuel tank harness con-
80) from platform harness con-
79).
0296), test for continuity between
form harness (WP 0209) and
pin 6 and pin 5 on fuel tank har-
instrument panel harness (WP
0260). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
fuel tank harness (WP 0170).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
0022-24