Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  733    734    735    736    737  738  739    740    741    742    743  
img
. . . . . . . . . .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
62. Remove Fuse #16 (Figure 4,
Facing Flood Lamp(s)
Item 1) from fuse panel (TM 5-
Do Not Work - Continued
2410-241-10).
Figure 4. Fuse #16.
0022
63. Using a digital multimeter (WP
1. If continuity is NOT found, pro-
0296), test for continuity between
ceed to step 74.
blades of Fuse #16.
2. If continuity is found, install Fuse
#16 on fuse panel (TM 5-2410-
241-10). Proceed to step 64.
64. Disconnect left rear flood lamp
harness connector TK-C3 (WP
0018, Figure 103) from fuel tank
harness connector TW-C3 (WP
0018, Figure 105).
65. Disconnect right rear flood lamp
harness connector TJ-C3 (WP
0018, Figure 104) from fuel tank
harness connector TW-C5 (WP
0018, Figure 106).
66. Install jumper wire between pin 3
and pin 4 on fuel tank harness
connector TW-C5 (WP 0018, Fig-
ure 106).