Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  735    736    737    738    739  740  741    742    743    744    745  
img
. . . . . . . . . . . . . . .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
74. Disconnect right rear flood lamp
Facing Flood Lamp(s)
harness connector TJ-C2 (WP
Do Not Work - Continued
0018, Figure 102) from right
ROPS-mounted forward facing
flood lamp.
75. Disconnect left rear flood lamp
harness connector TK-C2 (WP
0018, Figure 101) from left side
ROPS-mounted forward facing
flood lamp.
76. Disconnect platform harness con-
nector MA-C3 (WP 0018, Figure
21) from fuse panel harness con-
nector A-C1 (WP 0018,
Figure 22).
77. Turn main light switch to Flood-
light position (TM 5-2410-241-10).
78. Using digital multimeter (WP
1. If continuity is NOT found, replace
0296), test for continuity between
fuse panel harness (WP 0176).
pin 30 on platform harness con-
Replace Fuse #16 (TM 5-2410-
nector MA-C3 (WP 0018,
241-10). Ensure all harness con-
Figure 21) and machine ground.
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
2. If continuity is found, proceed to
step 79.
79. Disconnect fuel tank harness con-
nector TW-C7 (WP 0018,
Figure 80) from platform harness
connector MA-C23 (WP 0018,
Figure 79).
80. Using digital multimeter (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 81.
pin 6 and pin 5 on fuel tank har-
2. If continuity is NOT found, replace
ness connector TW-C7 (WP
platform harness (WP 0209) and
0018, Figure 80).
instrument panel harness (WP
0260). Replace Fuse #16 (TM 5-
2410-241-10). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
81. Disconnect left rear flood lamp
harness connector TK-C3 (WP
0018, Figure 103) from fuel tank
harness connector TW-C3 (WP
0018, Figure 105).
0022-25