MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
82. Using digital multimeter (WP
1. If continuity is found, replace left
Facing Flood Lamp(s)
0296), test for continuity between
rear flood lamp harness (WP
Do Not Work - Continued
pin 3 and pin 4 on left rear flood
0154). Replace Fuse #16 (TM 5-
lamp harness connector TK-C3
2410-241-10). Ensure all harness
(WP 0018, Figure 103).
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
2. If continuity is NOT found, pro-
ceed to step 83.
83. Disconnect right rear flood lamp
harness connector TJ-C3 (WP
0018, Figure 104) from fuel tank
harness connector TW-C5 (WP
0018, Figure 106).
84. Using digital multimeter (WP
1. If continuity is found, replace right
0296), test for continuity between
rear flood lamp harness (WP
pin 3 and pin 4 on right rear flood
0154). Replace Fuse #16 (TM 5-
lamp harness connector TJ-C3
2410-241-10). Ensure all harness
(WP 0018, Figure 104).
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
2. If continuity is NOT found, replace
fuel tank harness (WP 0170).
Replace Fuse #16 (TM 5-2410-
241-10). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).