TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Forward
26. Inspect inside of right ROPS-
1. If corrosion or damage is found,
Facing Flood Lamp(s)
mounted forward facing flood
replace right ROPS-mounted for-
Do Not Work - Continued
lamp for corrosion and damage.
ward facing flood lamp assembly
(WP 0252). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
2. If corrosion and damage is NOT
found, proceed to step 27.
0296), test for continuity between
step 28.
pin 1 and terminal 4 on right
ROPS-mounted forward facing
right ROPS-mounted forward fac-
ing flood lamp assembly (WP
180).
0252). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
0296), test for continuity between
ROPS-mounted forward facing
pin 2 and terminal 3 on right
flood lamp bulb (WP 0252).
ROPS-mounted forward facing
Ensure all harness connectors
are reconnected. Verify correct
180).
operation of machine (TM 5-2410-
241-10).
right ROPS-mounted forward fac-
ing flood lamp assembly (WP
0252). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
29. Turn main light switch to OFF
position (TM 5-2410-241-10).
30. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
31. Disconnect right rear flood lamp
harness connector TJ-C3 (WP
0018, Figure 104) from fuel tank
harness connector TW-C5 (WP
0022-17