TM 5-2410-241-23-1
0029
TEST STEP 2: POSITIVE CABLES CONTINUED
00029
16. Using a digital multimeter (WP 0296), measure voltage drop between arctic kit junction block terminal (Figure
15, Item 3) and ground terminal (Figure 15, Item 2) of battery disconnect switch. Voltage drop should be within
1 volt of value recorded in step 1.
a. If voltage drop is greater than 1 volt of value recorded in step 1, replace junction block cable (Figure 15,
Item 4) (WP 0287).
b. If voltage drop is within 1 volt of value recorded in step 1, replace arctic kit positive battery cable (Figure
15, Item 1) (WP 0287).
c.
Turn battery disconnect switch to OFF position (TM 5-2410-241-10).
d. Connect arctic kit positive battery cable (Figure 15, Item 3) on arctic kit batteries (Figure 15, Item 5).
e. With an assistant, install arctic kit battery cover (Figure 15, Item 2), and set two latches (Figure 15, Item 1)
on arctic kit battery cover (Figure 15, Item 2).
Figure 15. Arctic Kit Battery Cable Junction Block.
0029
END OF TASK
END OF WORK PACKAGE