TEST STEP 2: POSITIVE CABLES CONTINUED
00029
7. Remove two bolts (Figure 12, Item 2), washers (Figure 12, Item 3), and plate (Figure 12, Item 1) from machine.
8. Using a digital multimeter (WP 0296), measure voltage drop between breaker panel positive junction point
(Figure 12, Item 4) and negative battery post (Figure 12, Item 6). Voltage drop should be within 1 volt of value
recorded in step 1.
a. If voltage drop is greater than 1 volt of value recorded in step 1, replace positive battery cable (Figure 12,
Item 5) (WP 0159).
b. If voltage drop is within 1 volt of value recorded in step 1, proceed to step 9.
Figure 12. Breaker Panel Positive Junction Point.