TEST STEP 2: POSITIVE CABLES CONTINUED
00029
9. Using a digital multimeter (WP 0296), measure voltage drop between alternator positive cable end (Figure 13,
Item 2) and machine ground (Figure 13, Item 1). Voltage should be within 1 volt of value recorded in step 1.
a. If voltage drop is greater than 1 volt of value recorded in step 1, replace alternator positive cable (Figure
13, Item 3) (WP 0163).
b. If voltage drop is within 1 volt of value recorded in step 1, and arctic kit is installed, proceed to step 10;
otherwise, all positive battery cables and positive alternator cables are OK.