Figure 7. Arctic Kit Negative Battery Cable.
Figure 10. Left Side Positive Battery Cable Junction

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  944    945    946    947    948  949  950    951    952    953    954  
img
.
TM 5-2410-241-23-1
0029
TEST STEP 2: POSITIVE CABLES
00029
1. Using a digital multimeter (WP 0296), measure voltage between positive post (Figure 8, Item 1) and negative
post (Figure 8, Item 2) of the batteries (Figure 8, Item 3). Monitor and record voltage.
Figure 8. Positive and Negative Battery Voltage Test.
0029
2. Using a digital multimeter (WP 0296), measure voltage between positive terminal (Figure 9, Item 1) of starter
and ground terminal of starter (Figure 9, Item 2). Voltage drop should be within 1 volt of value recorded in
step 1.
a. If voltage drop is greater than 1 volt of value recorded in step 1, proceed to step 3.
b. If voltage drop is within 1 volt of value recorded in step 1, proceed to step 5.
Figure 9. Starter Terminals.
0029
3. Remove front floor plates (WP 0239).
0029-9