TEST STEP 1: GROUND CABLES CONTINUED
11. Remove cover (Figure 6, Item 1) from NATO slave receptacle (Figure 6, Item 3).
12. Using a digital multimeter (WP 0296), measure voltage between positive post (Figure 1, Item 1) of battery and
outer contact (Figure 6, Item 2) (negative side) of NATO slave receptacle (Figure 6, Item 3). Voltage drop
should be within 1 volt of value recorded in step 3 or the NATO slave receptacle ground cable is faulty.
a. If voltage drop is greater than 1 volt of value recorded in step 3, NATO slave receptacle ground cable is
faulty. Replace NATO slave receptacle ground cable (WP 0045).
b. If voltage drop is within 1 volt of value recorded in step 3, install NATO slave receptacle cover (Figure 6,
Item 1) and proceed to step 13.