TM 5-2410-241-23-3
0216
ASSEMBLY CONTINUED
N OT E
Install fittings as noted during disassembly.
34. Install new O-ring (Figure 29, Item 10) on diagnostic port fitting (Figure 29, Item 11).
35. Install diagnostic port fitting (Figure 29, Item 11) on elbow (Figure 29, Item 12).
36. Install cover and strap (Figure 29, Item 9) on diagnostic port fitting (Figure 29, Item 11).
37. Install new O-ring (Figure 29, Item 13) on fitting (Figure 29, Item 12).
38. Install elbow (Figure 29, Item 12) on T fitting (Figure 29, Item 6) and tighten nut (Figure 29, Item 14).
39. Install new O-ring (Figure 29, Item 7) on fitting (Figure 29, Item 2).
40. Install fitting (Figure 29, Item 2) on T fitting (Figure 29, Item 6).
41. Install new O-ring (Figure 29, Item 8) on sampling valve (Figure 29, Item 4).
42. Install sampling valve (Figure 29, Item 4) on fitting (Figure 29, Item 2) and tighten nut (Figure 29, Item 3).
43. Install two new O-rings (Figure 29, Item 5) on elbow (Figure 29, Item 1).
44. Install elbow (Figure 29, Item 1) on T fitting (Figure 29, Item 6).
Figure 29. Sampling Valve and Fittings Assembly.
0216