TM 5-2410-241-23-3
0220
REMOVAL
000220
WARN I N G
Contact with refrigerant can cause frostbite. Keep hands and face away to prevent
personal injury.
Protective face shield and gloves must always be worn when refrigerant lines are opened,
even if gauges indicate A/C system is empty.
Always use caution when disconnecting fittings Slowly loosen fitting in well-ventilated
.
area.
Do not smoke when servicing A/C or wherever refrigerant gas may be present.
Failure to follow these warnings may result in injury or death to personnel.
N OT E
Tag hoses to aid installation.
Cap and plug all hoses and lines to prevent contamination and leaks.
1. Recover the air conditioning system. Refer to Air Conditioning System Service (WP 0263).
2. Remove four bolts (Figure 1, Item 2), washers (Figure 1, Item 1), cover (Figure 1, Item 3) and gasket (Figure 1,
Item 4) from platform (Figure 1, Item 5). Discard gasket.
Figure 1. Cover.
0220