Figure 8. Cover.
Figure 2. Heater Hoses.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  341    342    343    344    345  346  347    348    349    350    351  
img
. . . . . . . . . . .
6
TM 5-2410-241-23-3
0221
FIELD MAINTENANCE INSTRUCTIONS
-
HEATER COIL REPLACEMENT
022
1
Removal, Cleaning and Inspection, Installation
INITIAL SETUP
Tools and Special Tools
References
0
0
Tool Kit, General Mechanic's
WP 0295
0
(WP 0302, Item 65)
0
Equipment Condition
0
Pan, Drain (S0255) (WP 0302, Item 68)
0
Machine parked (TM 5-2410-241-10)
0
Materials/Parts
0
Air conditioner evaporator coil removed
Antifreeze, Permanent, Ethylene Glycol, Inhib-
(WP 0220)
0
0
ited (WP 0303, Item 1)
Drawing Required
0
Cap Set, Protective (WP 0303, Item 4)
0
TM 5-2410-241-24P, Figure 105
0
Rag, Wiping (WP 0303, Item 24)
0
Estimated Time to Complete
Tag, Marker (WP 0303, Item 34)
0
0
6.5 Hr
0
REMOVAL
000221
1. Close two heater hose valves (Figure 1, Item 2) on heater hoses (Figure 1, Item 1).
Figure 1. Heater Hose Valves.
0221