AIR CONDITIONING LOW PRESSURE HOSES REPLACEMENT
Figure 2. Accumulator Hose to Evaporator Coil.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  490    491    492    493    494  495  496    497    498    499    500  
img
.
TM 5-2410-241-23-3
0242
COMPRESSOR HOSE TO ACCUMULATOR REMOVAL
000242
N OT E
Tag hoses to aid installation.
Clean exterior of hoses before removal to prevent contamination.
Cap and plug all hoses and lines to prevent contamination and leaks.
1. Loosen nut (Figure 1, Item 2) and disconnect hose (Figure 1, Item 1) from air conditioning compressor
(Figure 1, Item 13).
2. Remove O-ring (Figure 1, Item 3) from hose (Figure 1, Item 1). Discard O-ring.
3. Remove bolt (Figure 1, Item 5), washer (Figure 1, Item 4), and clip (Figure 1, Item 6) from machine, and clip
from hose (Figure 1, Item 1).
4. Remove bolt (Figure 1, Item 10), washer (Figure 1, Item 12), and clip (Figure 1, Item 11) from machine and clip
from hose (Figure 1, Item 1).
5. Loosen nut (Figure 1, Item 9) and disconnect hose (Figure 1, Item 1) from accumulator (Figure 1, Item 7).
6. Remove O-ring (Figure 1, Item 8) from hose (Figure 1, Item 1). Discard O-ring.
7. Remove hose (Figure 1, Item 1) from machine.
Figure 1. Compressor Hose to Accumulator.
0242
END OF TASK