TM 5-2410-241-23-3
0242
000242
N OT E
Tag hoses to aid installation.
Cap and plug all hoses and lines to prevent contamination and leaks.
1. Loosen nut (Figure 1, Item 2) and disconnect hose (Figure 1, Item 1) from air conditioning compressor
(Figure 1, Item 13).
2. Remove O-ring (Figure 1, Item 3) from hose (Figure 1, Item 1). Discard O-ring.
3. Remove bolt (Figure 1, Item 5), washer (Figure 1, Item 4), and clip (Figure 1, Item 6) from machine, and clip
from hose (Figure 1, Item 1).
4. Remove bolt (Figure 1, Item 10), washer (Figure 1, Item 12), and clip (Figure 1, Item 11) from machine and clip
from hose (Figure 1, Item 1).
5. Loosen nut (Figure 1, Item 9) and disconnect hose (Figure 1, Item 1) from accumulator (Figure 1, Item 7).
6. Remove O-ring (Figure 1, Item 8) from hose (Figure 1, Item 1). Discard O-ring.
7. Remove hose (Figure 1, Item 1) from machine.
Figure 1. Compressor Hose to Accumulator.
0242
END OF TASK