STARTER MOTOR REPLACEMENT
Figure 2. Starter and Ground Cables.

Field Maintenance Manual 2 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  468    469    470    471    472  473  474    475    476    477    478  
img
.
TM 5-2410-240-23-2
0095
REMOVAL
N OT E
Tag and mark cables to aid installation.
1. Position boot (Figure 1, Item 2) aside.
2. Remove nut (Figure 1, Item 1) and two positive cables (Figure 1, Items 4 and 3) from stud (Figure 1, Item 5).
Figure 1. Starter and Positive Cables.