Figure 25. Blade Angle Control Valve.
Figure 27. Valve Bank Assembly.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  240    241    242    243    244  245  246    247    248    249    250  
img
.
TM 5-2410-240-23-3
0197
ASSEMBLY CONTINUED
N OT E
Install O-rings as noted during removal.
22. Install four new O-rings (Figure 26, Item 8) on solenoid (Figure 26, Item 7).
N OT E
Install O-rings as noted during removal.
23. Install solenoid (Figure 26, Item 7), clamp (Figure 26, Item 6), and bolt (Figure 26, Item 5) on outlet manifold
(Figure 26, Item 1).
24. Install seven new O-rings (Figure 26, Item 4) and three fittings (Figure 26, Item 3) on outlet manifold
(Figure 26, Item 1).
25. Install outlet manifold (Figure 26, Item 1) and four nuts (Figure 26, Item 2) on valve bank (Figure 26, Item 9).
Figure 26. Outlet Manifold.
0197
END OF TASK