BLADE LIFT CYLINDER PRESSURE TEST CONTINUED
3. Open door (Figure 2, Item 2) (TM 5-2410-241-10).
N OT E
Transmission filter shown removed for clarity.
4. Remove protective cap (Figure 2, Item 3) from fitting (Figure 2, Item 6).
5. Remove protective cap (Figure 2, Item 4) from fitting (Figure 2, Item 5).
6. Connect 177-7861 hose (Figure 2, Item 8) coming from implement pump discharge pressure port (Figure 2,
Item 9) to fitting (Figure 2, Item 6).
7. Connect 177-7862 hose (Figure 2, Item 7) coming from signal pressure port (Figure 2, Item 1) to fitting
(Figure 2, Item 5).