• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 7. Doors.
Figure 1. Electrical Connector.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  279    280    281    282    283  284  285    286    287    288    289  
img
. . . . . . . . . . . . . . .
32
TM 5-2410-241-23-3
0216
FIELD MAINTENANCE INSTRUCTIONS
-
CONTROL MANIFOLD SERVICE
0
216
Removal, Disassembly, Cleaning and Inspection, Assembly, Installation, Control Manifold Accumulator
Charge Pressure Test, Accumulator Charging
INITIAL SETUP
Personnel
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
Two
0
(WP 0302, Item 65)
References
0
0
Charging Kit, Pressuring (Nitrogen)
WP 0295
(WP 0302, Item 16)
0
0
WP 0304
Coupling, Hose (1/4" NPT, Internal Thread)
0
(WP 0302, Item 17)
Equipment Condition
0
0
Fitting (WP 0302, Item 24)
0
Machine parked (TM 5-2410-241-10)
0
Gauge, Pressure (Pilot), Dial Indicating
Hydraulic system pressure released
(WP 0302, Item 31)
0
(WP 0186)
0
Hose Assembly; 6,000 psi (41, 500 kPa), 1/8-
Hydraulic system drained (WP 0184)
27-NPTF, 18 ft (549 cm) long
0
(WP 0302, Item 34)
Drawing Required
0
0
Wrench, Combination, 1 5/8" (S0794)
TM 5-2410-241-24P, Figure 81
0
(WP 0302, Item 68)
0
Estimated Time to Complete
Materials/Parts
0
0
4.5 Hr
0
Cap Set, Protective (WP 0303, Item 4)
0
Rag, Wiping (WP 0303, Item 24)
0
Tag, Marker (WP 0303, Item 34)
0
Tiedown Strap (WP 0303, Item 36)
0
O-ring (22)
0
0216-1