TM 5-2410-241-23-3
0216
DISASSEMBLY CONTINUED
N OT E
Note orientation and position of fittings to aid installation.
3. Remove elbow (Figure 5, Item 1) from T fitting (Figure 5, Item 6).
4. Remove two O-rings (Figure 5, Item 5) from elbow (Figure 5, Item 1). Discard O-rings
5. Loosen nut (Figure 5, Item 3) and remove sampling valve (Figure 5, Item 4) from fitting (Figure 5, Item 2).
6. Remove O-ring (Figure 5, Item 8) from sampling valve (Figure 5, Item 4). Discard O-ring.
7. Remove fitting (Figure 5, Item 2) from T fitting (Figure 5, Item 6).
8. Remove O-ring (Figure 5, Item 7) from fitting (Figure 5, Item 2). Discard O-ring.
9. Loosen nut (Figure 5, Item 14) and remove elbow (Figure 5, Item 12) from T fitting (Figure 5, Item 6).
10. Remove O-ring (Figure 5, Item 13) from fitting (Figure 5, Item 12). Discard O-ring.
11. Remove cover and strap (Figure 5, Item 9) from diagnostic port fitting (Figure 5, Item 11).
12. Remove diagnostic port fitting (Figure 5, Item 11) from elbow (Figure 5, Item 12).
13. Remove O-ring (Figure 5, Item 10) from diagnostic port fitting (Figure 5, Item 11) Discard O-ring.
Figure 5. Sampling Valve and Fittings Disassembly.
0216