img
.
TM 5-2410-241-23-3
0219
BLOWER MOTOR INSTALLATION CONTINUED
N OT E
Install connectors as tagged in removal.
3. Install harness and connect blower motor connector (Figure 9, Item 7) to blower harness connector (Figure 9,
Item 6).
4. Install grommet (Figure 9, Item 1) in cover (Figure 9, Item 2).
5. Install blower harness connector (Figure 9, Item 6) through grommet (Figure 9, Item 1) in cover (Figure 9,
Item 2).
6. Install blower motor (Figure 9, Item 5), three plates (Figure 9, Item 4), and six bolts (Figure 9, Item 3)
on cover (Figure 9, Item 2).
7. Install resistor. Refer to Resistor Installation in this work package.
8. Install temperature switch. Refer to Temperature Switch Installation in this work package.
Figure 9. Blower Motor Cover.
0219
END OF TASK
0219-8