Figure 9. Blower Motor Cover.
Figure 12. Blower Motor.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  329    330    331    332    333  334  335    336    337    338    339  
img
.
TM 5-2410-241-23-3
0219
RESISTOR INSTALLATION
000219
1. Install resistor (Figure 10, Item 3) and two bolts (Figure 10, Item 4) on plate (Figure 10, Item 2) and guard
(Figure 10, Item 1).
Figure 10. Resistor.
0219
N OT E
Install connectors as tagged in removal.
2. Connect blower harness connector (Figure 11, Item 6) on resistor (Figure 11, Item 7).
3. Install plate (Figure 11, Item 4), guard (Figure 11, Item 1), two washers (Figure 11, Item 3), and bolts
(Figure 11, Item 2) on cover (Figure 11, Item 5).
Figure 11. Resistor Connection.
0219
0219-9