HOSES REMOVAL CONTINUED
N OT E
Hose clamps are all removed using the same general method. This procedure covers
removal of one clamp from machine.
Note position of clamps to aid installation.
15. Disconnect hose (Figure 7, Item 2) and remove O-ring (Figure 7, Item 13) from pump (Figure 7, Item 1).
Discard O-ring.
16. Remove nut (Figure 7, Item 7), clamp (Figure 7, Item 12), and spacer (Figure 7, Item 8) from machine.
17. Remove bolt (Figure 7, Item 11), washer (Figure 7, Item 10), and bracket (Figure 7, Item 9) from machine.
18. Disconnect hose (Figure 7, Item 2) and remove O-ring (Figure 7, Item 6), elbow (Figure 7, Item 5), and O-ring
(Figure 7, Item 3) from demand fan manifold (Figure 7, Item 4). Discard O-rings.
19. Remove hose (Figure 7, Item 2) from machine.
Figure 7. Pump to Demand Fan Manifold.
0170
END OF TASK