Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  750    751    752    753    754  755  756    757    758    759    760  
img
. .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Flood Lamp Does
9. Inspect inside of engine flood
1. If corrosion or damage is found,
Not Work - Continued
lamp for corrosion and damage.
replace engine flood lamp assem-
bly (WP 0253). Ensure all harness
connectors are reconnected. Ver-
ify correct operation of machine
(TM 5-2410-241-10).
2. If corrosion and damage is NOT
found, proceed to step 10.
10. Using digital multimeter (WP
1. If continuity is found, proceed to
0296), test for continuity between
step 11.
pin 1 and terminal 4 on engine
2. If continuity is NOT found, replace
flood lamp (WP 0018, Figure
engine flood lamp assembly (WP
181).
0253). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
11. Using digital multimeter (WP
1. If continuity is found, replace
0296), test for continuity between
engine flood lamp bulb (WP
pin 2 and terminal 3 on engine
0253). Ensure all harness con-
flood lamp (WP 0018, Figure
nectors are reconnected. Verify
181).
correct operation of machine (TM
5-2410-241-10).
2. If continuity is NOT found, replace
engine flood lamp assembly (WP
0253). Ensure all harness con-
nectors are reconnected. Verify
correct operation of machine (TM
5-2410-241-10).
12. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
0022-40