Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ROPS Mounted Rearward
78. Disconnect right rear flood lamp
Facing Floodlamp(s) Do
harness connector TJ-C3 (WP
Not Work - Continued
0018, Figure 104) from fuel tank
harness connector TW-C5 (WP
79. Install a jumper wire between pin
1 and pin 2 on fuel tank harness
connector TW-C5 (WP 0018, Fig-
ure 106).
80. Disconnect platform harness con-
21) from fuse panel harness con-
22).
81. Turn main light switch to floodlight
position (TM 5-2410-241-10).
82. Turn rear facing floodlight switch
to ON position (TM 5-2410-241-
10).
1. If continuity is found, replace fuse
0296), test for continuity between
panel harness (WP 0176). Ensure
pin 27 on platform harness con-
all harness connectors are recon-
nected. Verify correct operation of
21) and machine ground.
machine (TM 5-2410-241-10).
ceed to step 84.
84. Disconnect instrument panel har-
Figure 100) from main light switch
1. If continuity is found, proceed to
0296), test for continuity between
step 86.
pin 2 and pin 6 on main light
switch.
main light switch (WP 0262).
Ensure all harness connectors
are reconnected. Verify correct
operation of machine (TM 5-2410-
241-10).
86. Disconnect instrument panel har-
Figure 109) from rear facing flood-
109).
0022-36