Figure 4. Disconnecting Steering Control Link.
Figure 6. Hose Removal.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  239    240    241    242    243  244  245    246    247    248    249  
img
. .
TM 5-2410-241-23-3
0212
REMOVAL CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure lifting device used is in good condition and of
suitable load capacity. Keep clear of heavy parts supported only by lifting device. Failure
to follow this warning may cause injury or death to personnel.
N OT E
Valve bank weighs approximately 100 lb (45 kg).
7. Remove cab (WP 0245).
8. Attach bracket link (Figure 5, Item 4) and lifting device on valve bank (Figure 5, Item 3).
9. Loosen tube nut (Figure 5, Item 1) and disconnect hose (Figure 5, Item 7) and O-ring (Figure 5, Item 2) from
valve bank (Figure 5, Item 3). Discard O-ring.
10. Remove four bolts (Figure 5, Item 5), and washers (Figure 5, Item 6) from valve bank bracket (Figure 5,
Item 8).
Figure 5.
Valve Bank Mounting.
0212
0212-5