Figure 34. Test Equipment Installation.
CONTROL MANIFOLD SERVICE - Continued

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  309    310    311    312    313  314  315    316    317    318    319  
img
. .
TM 5-2410-241-23-3
0216
ACCUMULATOR CHARGING
C AU T I O N
Dry nitrogen is the only gas approved for use in accumulator. Any other gas may cause
the accumulator to fail.
N OT E
Accumulator charge pressure should be 150 psi (1035 kPa) when temperature is 70F
(20C).
New accumulators ship discharged and must be charged. Once unit is properly charged, it
is considered a sealed unit and should never be recharged. If unit looses charge it should
be replaced.
Accumulator should only be charged on the bench.
1. Remove protective cap (Figure 35, Item 2) from valve (Figure 35, Item 1).
2. Attach nitrogen charging group to valve (Figure 35, Item 1).
3. Using nitrogen charging group, charge Accumulator to 150 psi (1,035 kPa) when temperature is 70F (20C).
4. Install protective cap (Figure 35, Item 2) on valve (Figure 35, Item 1).
5. Install accumulator (Figure 35, Item 3) on machine (WP 0217).
Figure 35. Accumulator.
0216
END OF TASK